Bolted End Plate Hot Rolled Beam
Instructions for interaction:
1. To zoom in and out Roll the centre wheel of the mouse.
2. To rotate Click and hold the left mouse button and move the mouse.
3. To move the model around the screen Click and hold the right mouse button and move the mouse.
Notes:
- Base plates and end plates welded to hot rolled sections require venting to allow pre-treatment fluids, zinc and air to escape during the galvanizing process. This will ensure that a high quality and uniform coating fully develops over the steel surface and eliminates the possibility of air pockets, zinc traps and bare spots.
- Corners between section and plate can accumulate zinc, create an air trap or trap pre-treatment fluids. This can result in a lower quality surface finish or bare spots. To avoid such issues, holes in the corners between the end plate and hot rolled section should be included in the fabrication. A hole in each corner is required to be at least 10 mm in diameter or larger, depending on the size of the section.
- If design requirements do not allow for end plate venting, then venting in the form of notches in the hot rolled section web may prove adequate. These notches must be fabricated as close as possible to the corners between the end plate and flange. This will eliminate possible zinc traps and air pockets. Notches should be in the form of semi circles of at least 20 mm in diameter or in the form of snipes of at least 25 mm x 25 mm in size.
- Stiffeners, cleats, flanges and gussets must all be designed into the fabrication such that they do not inhibit the flow of pre-treatment fluids and zinc. Cleats and flanges should be welded with adequate gaps in the hot rolled section channel to avoid zinc traps and air pockets. Venting in the form of snipes on the corners of stiffeners and gussets will allow the free flow of zinc and air resulting in a high quality and uniform surface coating finish. Snipes must be at least 25 x 25 mm in size and larger snipes may be required for larger sections.
- In all cases, the location of the vent holes must conform to the requirements of AS/NZS 5131 and AS 4100.
Previous: RHS/SHS Y Connection | Back to All Joints | Next: Bolted End Plate to Stiffened Column |